<p><span style=”font-family:Arial,Helvetica,sans-serif;”><strong><span style=”font-size:18px;”><span style=”color:#000000;”><span style=”margin: 0px; padding: 0px; box-sizing: border-box;”><span style=”margin: 0px; padding: 0px; box-sizing: border-box; background: none !important;”><span style=”margin: 0px; padding: 0px; box-sizing: border-box; font-weight: 600;”><span style=”margin: 0px; padding: 0px; box-sizing: border-box; background: none !important;”>Description :</span></span></span></span></span></span></strong></span></p>
<p><span style=”font-family:Arial,Helvetica,sans-serif;”><span style=”font-size:14px;”><span style=”color:#000000;”><span style=”margin: 0px; padding: 0px; box-sizing: border-box;”><span style=”margin: 0px; padding: 0px; box-sizing: border-box; background: none !important;”><span style=”margin: 0px; padding: 0px; box-sizing: border-box; font-weight: 600;”><span style=”margin: 0px; padding: 0px; box-sizing: border-box; font-weight: 100;”>Non-invasive Split Core Current Transformer AC Current Sensor 100A SCT-013-000. </span></span></span></span></span>The core is in two parts held together by clips or screws. The two parts are simply placed around the cable and assembled. There is no need to disconnect anything. Provided the current transformer has a burden connected, it can be installed on a live, insulated, current-carrying cable.</span></span></p>
<p><br style=”margin: 0px; padding: 0px; box-sizing: border-box;” />
<span style=”font-family:Arial,Helvetica,sans-serif;”><span style=”font-size:18px;”><span style=”color:#000000;”><span style=”margin: 0px; padding: 0px; box-sizing: border-box;”><span style=”margin: 0px; padding: 0px; box-sizing: border-box; background: none !important;”><strong>Feature</strong></span></span></span></span></span></p>
<ul>
<li>
<p><span style=”font-family:Arial,Helvetica,sans-serif;”><span style=”font-size:14px;”><span style=”color:#000000;”><span style=”margin: 0px; padding: 0px; box-sizing: border-box;”><span style=”margin: 0px; padding: 0px; box-sizing: border-box; background: none !important;”>Non-invasive current transformer</span></span></span></span></span></p>
</li>
<li>
<p><span style=”font-family:Arial,Helvetica,sans-serif;”><span style=”font-size:14px;”><span style=”color:#000000;”><span style=”margin: 0px; padding: 0px; box-sizing: border-box;”><span style=”margin: 0px; padding: 0px; box-sizing: border-box; background: none !important;”>Non-linearity ±3%(10%-120% rated input current)</span></span></span></span></span></p>
</li>
<li>
<p><span style=”font-family:Arial,Helvetica,sans-serif;”><span style=”font-size:14px;”><span style=”color:#000000;”><span style=”margin: 0px; padding: 0px; box-sizing: border-box;”><span style=”margin: 0px; padding: 0px; box-sizing: border-box; background: none !important;”>Suitable for lighting equipment, AC motors, air compressors, monitoring, current measurement, and protection</span></span></span></span></span></p>
</li>
<li>
<p><span style=”font-family:Arial,Helvetica,sans-serif;”><span style=”font-size:14px;”><span style=”color:#000000;”><span style=”margin: 0px; padding: 0px; box-sizing: border-box;”><span style=”margin: 0px; padding: 0px; box-sizing: border-box; background: none !important;”>Two forms of output current, voltage (voltage output built-in the sampling resistor)</span></span></span></span></span></p>
</li>
</ul>
<p><br style=”margin: 0px; padding: 0px; box-sizing: border-box; color: rgb(102, 102, 102); font-family: OpenSans, Arial; font-size: 14px;” />
<span style=”font-family:Arial,Helvetica,sans-serif;”><span style=”font-size:18px;”><span style=”color:#000000;”><span style=”margin: 0px; padding: 0px; box-sizing: border-box;”><span style=”margin: 0px; padding: 0px; box-sizing: border-box; background: none !important;”><strong><span style=”margin: 0px; padding: 0px; box-sizing: border-box; background: none !important;”><span style=”margin: 0px; padding: 0px; box-sizing: border-box; font-weight: 600;”>Specification :</span></span></strong></span></span></span></span></span></p>
<ul>
<li>
<p><span style=”font-family:Arial,Helvetica,sans-serif;”><span style=”font-size:14px;”><span style=”color:#000000;”><span style=”margin: 0px; padding: 0px; box-sizing: border-box;”><span style=”margin: 0px; padding: 0px; box-sizing: border-box; background: none !important;”>Reference project: OpenEnergyMonitor</span></span></span></span></span></p>
</li>
<li>
<p><span style=”font-family:Arial,Helvetica,sans-serif;”><span style=”font-size:14px;”><span style=”color:#000000;”><span style=”margin: 0px; padding: 0px; box-sizing: border-box;”><span style=”margin: 0px; padding: 0px; box-sizing: border-box; background: none !important;”>Core Material: Ferrite</span></span></span></span></span></p>
</li>
<li>
<p><span style=”font-family:Arial,Helvetica,sans-serif;”><span style=”font-size:14px;”><span style=”color:#000000;”><span style=”margin: 0px; padding: 0px; box-sizing: border-box;”><span style=”margin: 0px; padding: 0px; box-sizing: border-box; background: none !important;”>Dielectric Strength : 6000V AC/1min</span></span></span></span></span></p>
</li>
<li>
<p><span style=”font-family:Arial,Helvetica,sans-serif;”><span style=”font-size:14px;”><span style=”color:#000000;”><span style=”margin: 0px; padding: 0px; box-sizing: border-box;”><span style=”margin: 0px; padding: 0px; box-sizing: border-box; background: none !important;”>Input Current : 0A ~ 100A</span></span></span></span></span></p>
</li>
<li>
<p><span style=”font-family:Arial,Helvetica,sans-serif;”><span style=”font-size:14px;”><span style=”color:#000000;”><span style=”margin: 0px; padding: 0px; box-sizing: border-box;”><span style=”margin: 0px; padding: 0px; box-sizing: border-box; background: none !important;”>Output current: 0A ~ 50mA</span></span></span></span></span></p>
</li>
<li>
<p><span style=”font-family:Arial,Helvetica,sans-serif;”><span style=”font-size:14px;”><span style=”color:#000000;”><span style=”margin: 0px; padding: 0px; box-sizing: border-box;”><span style=”margin: 0px; padding: 0px; box-sizing: border-box; background: none !important;”>Anti-flaming rate: UL94-V0</span></span></span></span></span></p>
</li>
<li>
<p><span style=”font-family:Arial,Helvetica,sans-serif;”><span style=”font-size:14px;”><span style=”color:#000000;”><span style=”margin: 0px; padding: 0px; box-sizing: border-box;”><span style=”margin: 0px; padding: 0px; box-sizing: border-box; background: none !important;”>Mechanical strength: opening and closing times, no less than 1000 times (20 ℃)</span></span></span></span></span></p>
</li>
<li>
<p><span style=”font-family:Arial,Helvetica,sans-serif;”><span style=”font-size:14px;”><span style=”color:#000000;”><span style=”margin: 0px; padding: 0px; box-sizing: border-box;”><span style=”margin: 0px; padding: 0px; box-sizing: border-box; background: none !important;”>Output Plug: 3.5mm</span></span></span></span></span></p>
</li>
<li>
<p><span style=”font-family:Arial,Helvetica,sans-serif;”><span style=”font-size:14px;”><span style=”color:#000000;”><span style=”margin: 0px; padding: 0px; box-sizing: border-box;”><span style=”margin: 0px; padding: 0px; box-sizing: border-box; background: none !important;”>Opening Size (mm): 13 * 13</span></span></span></span></span></p>
</li>
<li>
<p><span style=”font-family:Arial,Helvetica,sans-serif;”><span style=”font-size:14px;”><span style=”color:#000000;”><span style=”margin: 0px; padding: 0px; box-sizing: border-box;”><span style=”margin: 0px; padding: 0px; box-sizing: border-box; background: none !important;”>Dielectric Strength : 6000V AC/1min</span></span></span></span></span></p>
</li>
<li>
<p><span style=”font-family:Arial,Helvetica,sans-serif;”><span style=”font-size:14px;”><span style=”color:#000000;”><span style=”margin: 0px; padding: 0px; box-sizing: border-box;”><span style=”margin: 0px; padding: 0px; box-sizing: border-box; background: none !important;”>Working Temperature: -25 – 70°C</span></span></span></span></span></p>
</li>
<li>
<p><span style=”font-family:Arial,Helvetica,sans-serif;”><span style=”font-size:14px;”><span style=”color:#000000;”><span style=”margin: 0px; padding: 0px; box-sizing: border-box;”><span style=”margin: 0px; padding: 0px; box-sizing: border-box; background: none !important;”>Cable Length : 110cm</span></span></span></span></span></p>
</li>
</ul>
<p> </p>
<p><span style=”font-family:Arial,Helvetica,sans-serif;”><strong><span style=”font-size:18px;”>Applications</span></strong></span></p>
<ul>
<li>
<p><span style=”font-family:Arial,Helvetica,sans-serif;”><span style=”font-size:14px;”>Home Automation and Control applications where Current measurement is needed.</span></span></p>
</li>
<li>
<p><span style=”font-family:Arial,Helvetica,sans-serif;”><span style=”font-size:14px;”>Suitable for the current measuring</span></span></p>
</li>
<li>
<p><span style=”font-family:Arial,Helvetica,sans-serif;”><span style=”font-size:14px;”>Monitoring and protection of AC motor</span></span></p>
</li>
<li>
<p><span style=”font-family:Arial,Helvetica,sans-serif;”><span style=”font-size:14px;”>Lighting equipment</span></span></p>
</li>
<li>
<p><span style=”font-family:Arial,Helvetica,sans-serif;”><span style=”font-size:14px;”>Air compressor</span></span></p>
</li>
</ul>
<p> </p>
<h2><span style=”font-family:Arial,Helvetica,sans-serif;”><strong><span style=”font-size:18px;”>Current Transformer Installation</span></strong></span></h2>
<p><span style=”font-family:Arial,Helvetica,sans-serif;”><img alt=”” src=”https://learn.openenergymonitor.org/electricity-monitoring/ct-sensors/files/CT-on-cable.jpg” style=”width: 600px; height: 210px;” /></span></p>
<p><span style=”font-family:Arial,Helvetica,sans-serif;”><span style=”font-size:14px;”>Installation as the right picture, the current transformer will not have current output since the electromagnetic has been neutralized.</span></span></p>
<p> </p>
<p><span style=”font-family:Arial,Helvetica,sans-serif;”><span style=”font-size:18px;”><a href=”https://learn.openenergymonitor.org/electricity-monitoring/ct-sensors/yhdc-sct-013-000-ct-sensor-report”><span style=”color:#3498db;”>More information (YHDC SCT-013-000 Current Transformer)</span></a></span></span></p>
<p><span style=”font-family:Arial,Helvetica,sans-serif;”><span style=”font-size:18px;”><a href=”https://www.poweruc.pl/blogs/news/non-invasive-sensor-yhdc-sct013-000-ct-used-with-arduino-sct-013″><span style=”color:#3498db;”>Tutorial (YHDC SCT013-000 CT USED WITH ARDUINO.)</span></a></span></span></p>
<p><span style=”font-family:Arial,Helvetica,sans-serif;”><span style=”font-size:18px;”><a href=”https://learn.openenergymonitor.org/electricity-monitoring/ct-sensors/files/YhdcCTReportIss6.pdf”><span style=”color:#3498db;”>Attachment (A Report on the properties of the Yhdc Current Transformer and its suitability for use with the OpenEnergy monitor.)</span></a></span></span></p>
Reviews
There are no reviews yet.