<p><span style=”font-family:Arial,Helvetica,sans-serif;”><span style=”font-size:18px;”><strong>Descriptions:</strong></span><br />
<span style=”font-size:14px;”>B3603 DC-DC CNC buck module is a fully digital display buck module, small size, high power, high efficiency, stable.</span></span></p>
<p><span style=”font-family:Arial,Helvetica,sans-serif;”><span style=”font-size:14px;”>Joined the high-speed micro-controller precision measurement and calculation, the output voltage and current value can be precisely regulated, built-in 10 groups memory locations, can be stored at any time, call up the parameters, easy to use.</span></span></p>
<p><span style=”font-family:Arial,Helvetica,sans-serif;”><span style=”font-size:14px;”>With four-digit eight segment LED digital tube, you can display the voltage, current, power, capacity and other parameters in real-time. </span></span></p>
<p><span style=”font-family:Arial,Helvetica,sans-serif;”><span style=”font-size:14px;”>Meanwhile, the module has an automatic output after power on and auto-rotate display parameters function, etc., can be turned on or off according to need of use.</span></span></p>
<p> </p>
<p> </p>
<p><span style=”font-family:Arial,Helvetica,sans-serif;”><span style=”font-size:18px;”><strong>Features & spec:</strong></span></span></p>
<ul>
<li>
<p><span style=”font-family:Arial,Helvetica,sans-serif;”><span style=”font-size:14px;”>Module type: Non-isolated Buck</span></span></p>
</li>
<li>
<p><span style=”font-family:Arial,Helvetica,sans-serif;”><span style=”font-size:14px;”>Input voltage: 6 ~ 40V (input voltage must 1.5V or higher than output voltage)</span></span></p>
</li>
<li>
<p><span style=”font-family:Arial,Helvetica,sans-serif;”><span style=”font-size:14px;”>Output voltage: 0 ~ 36V</span></span></p>
</li>
<li>
<p><span style=”font-family:Arial,Helvetica,sans-serif;”><span style=”font-size:14px;”>Output current: 0 ~ 3A (stable working current is 2A, continuous long high power working need to strengthen cooling)</span></span></p>
</li>
<li>
<p><span style=”font-family:Arial,Helvetica,sans-serif;”><span style=”font-size:14px;”>Voltage regulator / display resolution: 0.01V</span></span></p>
</li>
<li>
<p><span style=”font-family:Arial,Helvetica,sans-serif;”><span style=”font-size:14px;”>Power Display minimum resolution: 0.001W</span></span></p>
</li>
<li>
<p><span style=”font-family:Arial,Helvetica,sans-serif;”><span style=”font-size:14px;”>Switching frequency: 150KHZ</span></span></p>
</li>
<li>
<p><span style=”font-family:Arial,Helvetica,sans-serif;”><span style=”font-size:14px;”>Short circuit protection: Constant</span></span></p>
</li>
<li>
<p><span style=”font-family:Arial,Helvetica,sans-serif;”><span style=”font-size:14px;”>Operating temperature: -40 ° C to + 85 ° C</span></span></p>
</li>
<li>
<p><span style=”font-family:Arial,Helvetica,sans-serif;”><span style=”font-size:14px;”>Control: Digital Control + Digital Display</span></span></p>
</li>
<li>
<p><span style=”font-family:Arial,Helvetica,sans-serif;”><span style=”font-size:14px;”>Conversion efficiency: 92%</span></span></p>
</li>
<li>
<p><span style=”font-family:Arial,Helvetica,sans-serif;”><span style=”font-size:14px;”>Current Regulation / Display Resolution: 0.001A</span></span></p>
</li>
<li>
<p><span style=”font-family:Arial,Helvetica,sans-serif;”><span style=”font-size:14px;”>Capacity Display minimum resolution: 0.001AH</span></span></p>
</li>
<li>
<p><span style=”font-family:Arial,Helvetica,sans-serif;”><span style=”font-size:14px;”>Output ripple: ≤ 50mv</span></span></p>
</li>
<li>
<p><span style=”font-family:Arial,Helvetica,sans-serif;”><span style=”font-size:14px;”>Weight: 43g</span></span></p>
</li>
</ul>
<p> </p>
<p> </p>
<p><span style=”font-family:Arial,Helvetica,sans-serif;”><span style=”font-size:18px;”><strong>Display description:</strong></span></span></p>
<ul>
<li>
<p><span style=”font-family:Arial,Helvetica,sans-serif;”><span style=”font-size:14px;”>00.00: voltage value, 00.00 ~ 36.00V</span></span></p>
</li>
<li>
<p><span style=”font-family:Arial,Helvetica,sans-serif;”><span style=”font-size:14px;”>0.000: current value, 0.000 ~ 3.000A</span></span></p>
</li>
<li>
<p><span style=”font-family:Arial,Helvetica,sans-serif;”><span style=”font-size:14px;”>P.000, P0.00, P00.0, P000: power value, unit W, decimal point position changes with the power position changes.</span></span></p>
</li>
</ul>
<p><span style=”font-family:Arial,Helvetica,sans-serif;”><span style=”font-size:14px;”><strong>For example</strong>: P.123 means 0.123W, P1.23 means 1.23W, P12.3 means 12.3W, P102 means 102W.<br />
C.000, C0.00, C00.0, C000: capacity value, unit AH, decimal point position is changed with the change of the capacity.<br />
<strong>For example</strong>: C.123 means 0.123AH, C1.23 means 1.23AH, C12.3 means 12.3AH, C123 means 123AH.</span></span></p>
<p> </p>
<ul>
<li>
<p><span style=”font-family:Arial,Helvetica,sans-serif;”><span style=”font-size:14px;”>–0–, –1–, –2-: Special features 0, 1, 2</span></span></p>
</li>
<li>
<p><span style=”font-family:Arial,Helvetica,sans-serif;”><span style=”font-size:14px;”>–y-: Open the special features</span></span></p>
</li>
<li>
<p><span style=”font-family:Arial,Helvetica,sans-serif;”><span style=”font-size:14px;”>–n-: Close the special function</span></span></p>
</li>
<li>
<p><span style=”font-family:Arial,Helvetica,sans-serif;”><span style=”font-size:14px;”>SA.- * (* means 0 to 9): Save the parameters to the storage location of 0 to 9 in any one storage location</span></span></p>
</li>
<li>
<p><span style=”font-family:Arial,Helvetica,sans-serif;”><span style=”font-size:14px;”>Lo.- * (* means 0 to 9): Recall stored locations 0-9 arbitrary set of parameters</span></span></p>
</li>
</ul>
<p> </p>
<p> </p>
<p><span style=”font-family:Arial,Helvetica,sans-serif;”><span style=”font-size:18px;”><strong>Usage:</strong></span><br />
<span style=”font-size:14px;”>Connect the input and output correctly, ensure that the input voltage is within the required range, the reverse is strictly prohibited,<br />
if you are afraid of reversed damage you can concatenate more than 3A diode.</span></span></p>
<p> </p>
<p> </p>
<p><span style=”font-family:Arial,Helvetica,sans-serif;”><span style=”font-size:18px;”><strong>How to set the voltage and current values:</strong></span></span></p>
<ol>
<li>
<p><span style=”font-family:Arial,Helvetica,sans-serif;”><span style=”font-size:14px;”>Boot default display is Voltage Set Value. Voltage value display as "00.00", the unit is "V". Press the "SET" button to switch to the Current Set Value,</span></span></p>
</li>
<li>
<p><span style=”font-family:Arial,Helvetica,sans-serif;”><span style=”font-size:14px;”>the current value display format is "0.00", the unit is "A", press button to increase the set value, press the button to decrease the value,</span></span></p>
</li>
<li>
<p><span style=”font-family:Arial,Helvetica,sans-serif;”><span style=”font-size:14px;”>short press accurately set, long press can quickly set.</span></span></p>
</li>
<li>
<p><span style=”font-family:Arial,Helvetica,sans-serif;”><span style=”font-size:14px;”>After the setting is completed press "OK" button to output.</span></span></p>
</li>
<li>
<p><span style=”font-family:Arial,Helvetica,sans-serif;”><span style=”font-size:14px;”>Under the output state when display the voltage value press the button can increase the output voltage,</span></span></p>
</li>
<li>
<p><span style=”font-family:Arial,Helvetica,sans-serif;”><span style=”font-size:14px;”>pressing the button can reduce the output voltage. Press the button to increase the Current Setting Value when the current value is displayed,</span></span></p>
</li>
<li>
<p><span style=”font-family:Arial,Helvetica,sans-serif;”><span style=”font-size:14px;”>press the button can reduce current setting, short press accurately setting, long press can quickly setting.</span></span></p>
</li>
<li>
<p><span style=”font-family:Arial,Helvetica,sans-serif;”><span style=”font-size:14px;”>Under the output state short press "OK" button to switch display voltage and current value,</span></span></p>
</li>
<li>
<p><span style=”font-family:Arial,Helvetica,sans-serif;”><span style=”font-size:14px;”>long press "OK" button for 3 seconds to auto-rotate display, long press again to cancel the rotate display. In the rotate display,</span></span></p>
</li>
<li>
<p><span style=”font-family:Arial,Helvetica,sans-serif;”><span style=”font-size:14px;”>press keys are invalid.</span></span></p>
</li>
<li>
<p><span style=”font-family:Arial,Helvetica,sans-serif;”><span style=”font-size:14px;”>Under the output state, press the "SET" button to turn off the output.</span></span></p>
</li>
<li>
<p><span style=”font-family:Arial,Helvetica,sans-serif;”><span style=”font-size:14px;”>Above are a simple model of the module, which is the default mode,</span></span></p>
</li>
<li>
<p><span style=”font-family:Arial,Helvetica,sans-serif;”><span style=”font-size:14px;”>you can see it is very simple and easy to use if you want to save the recall stored values or see the power,</span></span></p>
</li>
<li>
<p><span style=”font-family:Arial,Helvetica,sans-serif;”><span style=”font-size:14px;”>capacity and other parameters in the state of the output, you need to convert to full-function mode.</span></span></p>
</li>
</ol>